Past exam question: 2078 Kartik, Q5(b)
Open in the Padhaiko appQuestion
Explain polar RZ line coding scheme with example.
Solution
Operating Principle of Polar Return-to-Zero (Polar RZ): In Polar RZ (Return-to-Zero):
- Three distinct voltage levels are used: positive voltage , negative voltage , and zero voltage .
- Binary 1: Transmitted as for the first half of the bit interval () and returns to for the second half ().
- Binary 0: Transmitted as for the first half of the bit interval () and returns to for the second half ().
Because the voltage returns to zero midway through every single bit period regardless of whether the bit is a 0 or a 1, every bit interval contains a guaranteed voltage transition.
Waveform Representation for Bitstream 1 0 1 1 0:
| Bit | First Half Interval () | Second Half Interval () |
|---|---|---|
1 | ||
0 | ||
1 | ||
1 | ||
0 |
Key Feature: Offers excellent synchronization because transitions occur in every bit cell, but requires twice the bandwidth of NRZ due to pulse width halving ().
Answer:
In Polar RZ, a bit interval of duration uses three voltage levels:
- Bit
1: for the first half interval, returning to for the second half. - Bit
0: for the first half interval, returning to for the second half.
Guarantees a mid-bit transition for synchronization, at the expense of doubled bandwidth.