Electrical Equipment
Open in the Padhaiko app8.1 Voltmeter and Ammeter: Types and Working Principle
Electrical measuring instruments indicate fundamental circuit quantities—potential difference (voltmeter) and electric current (ammeter)—by converting electrical energy into a readable mechanical deflection or a digital numerical readout.
Voltmeter: Working Principle and Connection
Voltmeter
A voltmeter is an instrument used to measure electrical potential difference (voltage) between two points in a circuit. It must always be connected in parallel across the circuit element being measured and must possess very high internal resistance so that it draws negligible current and leaves the circuit voltage undisturbed.
If a voltmeter of resistance is connected in parallel across a load of impedance , the equivalent parallel impedance is . Because , we have , so the loading effect is minimal and the meter accurately senses the true load voltage. Connecting a voltmeter in series would introduce an enormous resistance into the branch, effectively opening the circuit and stopping current flow.
According to construction and operating principle, voltmeters are classified into seven main types (pages="notes"):
- Permanent Magnet Moving Coil (PMMC) Voltmeter
- Moving Iron (MI) Voltmeter
- Electrodynamometer-Type Voltmeter
- Rectifier-Type Voltmeter
- Induction-Type Voltmeter
- Electrostatic-Type Voltmeter
- Digital Voltmeter (DVM)
Ammeter: Working Principle and Connection
Ammeter
An ammeter (short for ampere-meter) is an instrument used to measure electric current in amperes. It must always be connected in series with the circuit branch carrying the current and must possess very low internal resistance and inductive reactance to minimize voltage drop () and power loss ().
Ideally, an ammeter would have zero impedance so it introduces zero voltage drop. Connecting an ammeter in parallel across a voltage source creates a near-short-circuit path through its low-resistance coil, drawing excessive fault current that can burn out the instrument.
Depending on construction, ammeters are mainly classified into (pages="notes"):
- Permanent Magnet Moving Coil (PMMC) Ammeter
- Moving Iron (MI) Ammeter
- Electrodynamometer-Type Ammeter
- Rectifier-Type Ammeter
Permanent Magnet Moving Coil (PMMC) / D'Arsonval Instruments
PMMC Working Principle
A PMMC (D'Arsonval) instrument operates on the electromagnetic motor principle: when a current-carrying coil is placed in the uniform radial magnetic field of a permanent magnet, a mechanical deflecting force acts on its sides, producing a torque that rotates the pivoted coil and moves a pointer across a calibrated scale.
For a rectangular coil of turns, length , breadth (coil area ), carrying current in a magnetic flux density , the deflecting torque is:
For a PMMC voltmeter, (where is the total meter circuit resistance), so . Restoring torque from the phosphor-bronze control springs is . At steady state ():
giving a uniform (linear) scale. Because reversing current polarity reverses the torque direction, a PMMC movement measures DC quantities only (unless paired with a rectifier for AC).
- Advantages: Linear (uniform) scale, low power consumption, high accuracy, effective eddy-current damping via the aluminium coil former, and easy range extension (
pages="notes"). - Disadvantages: Measures DC only (cannot read AC directly), higher cost, and delicate spring/jewel movement (
pages="notes").
Extension of Range in PMMC Instruments
Range Extension Using Series Multiplier and Shunt
- Voltmeter Range Extension (Series Multiplier ): To extend a PMMC movement of resistance and full-scale voltage to read a higher voltage , connect a high non-inductive resistance in series:
- Ammeter Range Extension (Parallel Shunt ): To extend a PMMC movement of resistance and full-scale current to read a higher total current , connect a low-resistance manganin shunt in parallel so that bypasses the coil:
Moving Iron (MI) Instruments
Moving Iron (Attraction and Repulsion) Principle
A Moving Iron (MI) instrument passes the measurand current (or a proportional fraction of voltage-driven current) through a stationary field coil to magnetize one or two soft-iron elements. Because the magnetic force is always attractive or repulsive in the same sense regardless of current polarity, MI meters work on both AC and DC.
MI instruments exist in two structural forms (pages="notes"):
- Attraction Type: An unmagnetized soft-iron vane mounted on a pivoted spindle is drawn into the magnetic field inside a stationary coil when current flows, rotating the attached pointer.
- Repulsion Type: Two soft-iron vanes (one fixed, one movable) placed side by side inside the coil are magnetized with the same polarity along their adjacent ends, creating mutual magnetic repulsion that drives the movable vane and pointer. Repulsion-type meters are generally more sensitive because the vanes sit in the region of maximum field strength (
pages="book 21").
If the coil has self-inductance varying with deflection angle , the deflecting torque from magnetic energy gradient is:
Equating this to spring controlling torque gives:
Because (non-negative), the pointer deflects in one direction for both polarities, making MI meters RMS-reading on AC and DC, though the scale is non-linear (cramped near zero). As an ammeter, the coil has a few turns of thick wire (low resistance to carry heavy current); as a voltmeter, it has many turns of fine wire (high resistance to draw minimal current) (pages="book 21").
- Advantages: Measures both AC and DC, inexpensive, robust construction, and low friction error (
pages="notes"). - Disadvantages: Non-uniform scale, waveform/frequency errors on AC, and noticeable hysteresis error in DC measurements (hence mainly used for AC) (
pages="notes").
Other Voltmeter and Ammeter Types
| Instrument Type | Operating Principle | Supply | Key Characteristics |
|---|---|---|---|
| Electrodynamometer | Interaction between magnetic fields of a fixed coil and a moving coil (). | AC & DC | High precision transfer instrument; non-linear square-law scale (). |
| Rectifier Type | Bridge rectifier converts AC to unidirectional current measured by a sensitive PMMC movement. | AC (and DC) | High sensitivity and low power loss for audio/low-voltage AC; calibrated for sinusoidal RMS. |
| Induction Type | Eddy currents induced in an aluminium disc by two phase-shifted AC fluxes produce torque. | AC only | Robust switchboard meter; uniform angular deflection up to , higher power loss. |
| Electrostatic Type | Electrostatic attraction between oppositely charged plates (). | AC & DC (Voltmeter only) | Draws virtually zero DC current (infinite input resistance); suited for high voltages (kV). |
| Digital Voltmeter (DVM) | Converts analog input voltage to binary via an ADC and displays digits on LED/LCD. | DC (AC via rectifier) | Very high input impedance (), no parallax error, high resolution. |
8.2 Energy Meter: Types and Working Principle
Energy Meter (Watt-Hour Meter)
An energy meter (also called a watt-hour meter) is an integrating instrument that measures the total electrical energy consumed by a circuit over a time interval:
Traditional electromechanical energy meters are divided into three classes (pages="book 160"):
- Electrolytic meters (DC only; measure ampere-hours by electrochemical deposition)
- Motor meters (DC commutator motor meters and AC induction-type meters—the most widespread)
- Clock meters (pendulum clock speed varied by electromagnetic coils)
Modern utility installations also widely deploy static (electronic/digital) smart energy meters that sample voltage and current with ADCs, compute digitally, and log kWh without moving parts (pages="added").
Induction-Type Single-Phase Energy Meter
The induction-type energy meter is the standard electromechanical meter for single-phase AC energy measurement.
Construction
- Driving System (Two Laminated Electromagnets): (
pages="book 160")- Series Magnet (Current Coil): Wound with a few turns of thick wire connected in series with the load. Its alternating flux is proportional to and in phase with load current .
- Shunt Magnet (Voltage/Pressure Coil): Wound with many turns of fine wire connected in parallel across the supply. Because its coil is highly inductive, its flux is proportional to supply voltage and lags by .
- Moving System (Thin Aluminium Disc): Mounted on a vertical spindle in the air gap between the series and shunt magnets so it rotates continuously as it cuts both leakage fluxes (
pages="book 160"). (Unlike indicating meters, an energy meter has no control spring, allowing uninterrupted rotation (pages="added").) - Lag Adjuster: A copper shading band (ring) fitted around the central limb of the shunt magnet. Its position is adjusted so that the shunt flux lags the applied voltage by exactly (
pages="book 160"). - Braking & Registering System: A permanent braking magnet (creating eddy-current drag torque on the rotating disc) and a gear-train/cyclometer register counting disc revolutions as kilowatt-hours (
pages="added").
AC Supply (V)
| |
| +----+----+
| | Shunt | (Many turns, fine wire -> Flux Phi_2 lags V by 90 deg)
| | Magnet | [Copper Lag-Adjuster Band on central limb]
| +----+----+
| |
=======+====[ Aluminium Disc ]==== (Spindle + Gear Register + Brake Magnet)
|
+----+----+
| Series | (Few turns, thick wire -> Flux Phi_1 in phase with I)
| Magnet |-----> Load (I)
+---------+Working Principle and Torque Derivation
Let load current lag supply voltage by phase angle (pages="book 161-162"):
- The shunt flux (lagging by ) induces an eddy EMF in the aluminium disc lagging by ; similarly, series flux induces eddy EMF lagging by .
- Neglecting the inductance of the eddy-current paths, eddy currents and are in phase with and respectively.
- From the phasor geometry (
pages="book 161-162"), the phase angle between and is , while the angle between and is . - Interaction of each flux with the other's eddy current produces two opposing torques:
- The net driving torque on the disc is:
- Since , , , and :
At steady rotation speed (revolutions per second), the eddy-current braking torque balances , giving . Integrating speed over time yields total disc revolutions . If is the meter constant (in ), then:
8.3 Frequency Meter: Types and Working Principle
Frequency Meter
A frequency meter is an electrical/electronic instrument that measures and displays the frequency (in hertz, ) of a periodic AC voltage or current signal.
Common types of frequency meters include (pages="book 162"):
- Mechanical Resonance (Vibrating Reed) Type Frequency Meter
- Electrical Resonance Type Frequency Meter:
- Ferrodynamic-type frequency meter
- Electrodynamometer-type frequency meter
- Weston Frequency Meter (moving-iron ratiometer type)
- Ratiometer-Type Frequency Meter
- Saturable Core Frequency Meter
- Digital Frequency Counter (counts zero-crossings over a precision crystal timebase gate) (
pages="added")
Ferrodynamic-Type (Electrical Resonance) Frequency Meter
Construction
A ferrodynamic frequency meter consists of (pages="book 162-163"):
- A laminated iron core of varying cross-section (tapered along its length).
- A fixed magnetizing coil mounted at one end of the core and connected directly across the AC supply whose frequency is to be measured.
- A moving (pivoted) coil carrying a pointer over a calibrated scale (LF–NF–HF), able to swing freely over the tapered iron core without any control spring.
- A fixed capacitor connected in series with the moving coil.
Working Principle
When the magnetizing coil is connected across the supply (pages="book 163-165"):
- Supply current creates an alternating flux in the iron core (in phase with ).
- This flux induces an EMF in the moving coil that lags by .
- Because the moving-coil circuit contains its self-inductance (which varies with coil position on the tapered core) and series capacitor , the moving-coil current lags or leads by an angle :
- If (inductive), lags by , so the angle between and is .
- If (capacitive), leads by , so the angle between and is .
- If (electrical resonance), and is in phase with (exact from and ).
- The deflecting torque on the moving coil is proportional to . At resonance (, ), , so net torque is zero and the pointer comes to rest:
- Notice that the self-inductance of the moving coil decreases as it moves away from the magnetizing coil (smaller core cross-section / weaker coupling) and increases as it moves closer (
pages="book 164-165"):- If supply frequency increases: decreases (). The resulting torque pushes the moving coil away from the magnetizing coil until drops enough that again, indicating the higher frequency.
- If supply frequency decreases: increases (). The opposite torque pulls the moving coil toward the magnetizing coil until increases to restore resonance, indicating the lower frequency.
Other Common Frequency Meters
| Type | Principle of Operation | Key Characteristics |
|---|---|---|
| Vibrating Reed (Mechanical Resonance) | Several thin steel reeds with slightly different natural mechanical frequencies sit near an AC electromagnet excited by the supply. The reed whose natural frequency matches (or with DC bias) vibrates with maximum amplitude. | Very rugged, unaffected by supply voltage waveform; discrete steps (e.g., in increments). |
| Weston Frequency Meter | Two fixed coils mounted at (one in series with a resistor , the other with an inductor ) act on a single soft-iron needle without control springs. As changes, changes the current ratio, shifting the resultant magnetic axis and needle angle. | Smooth continuous pointer indication; independent of supply voltage magnitude. |
8.4 Wattmeter: Types and Working Principle
Wattmeter
A wattmeter is an instrument that combines the functions of an ammeter and a voltmeter to measure real (active) electrical power () directly in watts. It has two coils: a low-resistance current coil (CC) connected in series with the load, and a high-resistance pressure/potential coil (PC) connected in parallel across the load via a series non-inductive resistor .
I_c = I (Current Coil, CC)
(+) ----o-----[=== CC ===]-----+-----> Load
| |
V I_p |
| +---[ PC ]---[R]--+
(-) ----o----+-----------------+-----> Load Return
(Pressure Coil in series with high non-inductive R)A wattmeter reading is proportional to current coil current, pressure coil voltage, and the cosine of the phase angle between them (pages="book 157"). Strictly speaking, the meter also includes the small power lost in whichever coil sits on the load side (either or ), though this error is normally small and can be compensated (pages="book 157").
There are four main types of wattmeter (pages="book 157"):
- Dynamometer-Type Wattmeter (most widely used for both AC and DC)
- Induction-Type Wattmeter (AC only; robust switchboard meter using two shaded/phase-shifted electromagnets acting on an aluminium disc with spring control) (
pages="added") - Electrostatic-Type Wattmeter (uses quadrant electrometer; suited for very low power factor or high-voltage dielectric loss measurements) (
pages="added") - Thermal-Type Wattmeter (uses thermocouples heated by and combinations) (
pages="added")
Dynamometer-Type Wattmeter
Construction
A dynamometer wattmeter consists of (pages="book 158"):
- Fixed Coil (Current Coil): Divided into two identical air-cored circular coils connected in series carrying the load current so that a uniform magnetic field exists between them.
- Moving Coil (Pressure/Potential Coil): A light circular coil of fine wire pivoted on a spindle between jewel bearings inside the fixed-coil field, connected across the supply through a high non-inductive series resistor .
- Control Springs: Two spiral hairsprings provide the restoring torque () and also serve as electrical leads to the moving coil.
- Pointer and Scale: Attached to the spindle, moving across a uniformly calibrated wattage scale.
Working Principle: DC and AC Power Measurement
1. DC Measurement: (pages="book 158-159") Let supply voltage be , load current be (assuming ), and pressure-coil current be . Because the fixed-coil flux and moving-coil flux , the deflecting torque is:
2. AC Measurement: (pages="book 159") Let instantaneous supply voltage be and load current (at lagging power factor ) be . Because the moving inertia cannot follow rapid oscillations, the pointer responds to the average deflecting torque over one cycle:
Equating average deflecting torque to spring restoring torque gives , yielding a uniform (linear) power scale for both AC and DC.
Worked Out Examples
1
A PMMC meter movement has an internal coil resistance and requires a full-scale deflection current of . Calculate: (a) the series multiplier resistance needed to convert it into a DC voltmeter; (b) the parallel shunt resistance needed to convert it into a DC ammeter.
Voltmeter range extension (series multiplier ): The voltage across the movement at full-scale deflection is . The multiplying factor for is :
Ammeter range extension (parallel shunt ): For a full-scale current , the shunt carries while sharing the same voltage :
(a) ( in series); (b) ( in parallel).
2
A dynamometer-type wattmeter measures the power of a single-phase AC load supplied at (RMS) drawing (RMS) at a lagging power factor . The pressure-coil circuit has a total non-inductive resistance , and the pressure coil is connected directly across the load (on the load side of the current coil). Find (a) the true load power, (b) the power lost in the pressure coil, and (c) the wattmeter reading and percentage error.
True load power:
Power consumed by the pressure coil: Since the pressure coil is connected directly across the load, the current coil carries both the load current and the pressure-coil current:
Wattmeter reading and percentage error:
(a) , (b) , (c) reading with error (reads high).
3
A single-phase induction-type energy meter has a meter constant . It supplies a constant load of at and lagging power factor for , during which the aluminium disc makes revolutions. Calculate (a) the true energy consumed in , (b) the expected disc revolutions, and (c) the percentage error of the meter.
True power and energy consumed:
In , the true energy is:
Expected revolutions and percentage error:
(a) , (b) , (c) (meter runs slow).
4
In a ferrodynamic-type electrical resonance frequency meter, the moving coil is connected in series with a fixed capacitor . Calculate the self-inductance of the moving coil at its equilibrium position when the supply frequency is (a) and (b) .
Resonance condition: At equilibrium, zero torque occurs when the moving-coil inductive reactance equals the capacitive reactance ():
Evaluating at and :
- At :
- At :
Because , the moving coil automatically shifts away from the magnetizing coil toward the narrower part of the iron core when frequency rises.
(a) at ; (b) at .
Exercises
Exercises
Why must a voltmeter have very high resistance and be connected in parallel, whereas an ammeter must have very low resistance and be connected in series? Compare PMMC and Moving Iron (MI) instruments on working principle, scale linearity, and AC/DC suitability.
Connection and internal resistance rules:
- Voltmeter: Connected in parallel across the component whose potential difference is measured. Very high internal resistance () ensures negligible bypass current and minimal loading error.
- Ammeter: Connected in series with the branch carrying the current. Very low internal impedance minimizes voltage drop () and power loss.
PMMC vs. Moving Iron comparison:
- PMMC: Fixed permanent magnet and moving coil; , giving a linear scale; reverses deflection if polarity reverses, so DC only; high accuracy and low power loss, higher cost.
- MI: Stationary coil magnetizes soft-iron vane(s) (attraction or repulsion); , giving a non-linear (square-law) scale; unidirectional torque works on both AC and DC (mainly AC due to DC hysteresis error); cheap and robust.
A voltmeter sits in parallel with high resistance to avoid loading the circuit, while an ammeter sits in series with low impedance to avoid voltage drop. PMMC gives a linear scale for DC only, whereas MI gives a non-linear scale suitable for both AC and DC.
A PMMC instrument with coil resistance gives full-scale deflection at . Find the resistance required to use it as (a) a DC voltmeter, and (b) a DC ammeter.
Series multiplier for voltmeter:
Parallel shunt for ammeter:
(a) in series; (b) in parallel.
Explain the construction and working principle of a single-phase induction-type energy meter. What is the function of the copper lag-adjuster band on the shunt magnet?
Construction: It consists of (1) a series magnet (thick current coil carrying load current , producing flux in phase with ), (2) a shunt magnet (fine voltage coil across supply , producing flux lagging by ), (3) a thin aluminium disc on a vertical spindle between the magnets, (4) a copper lag-adjuster band on the shunt magnet's central limb, and (5) a permanent braking magnet plus gear-train register.
Working principle and role of the lag adjuster: Fluxes and induce eddy currents and in the aluminium disc. Their interaction creates net driving torque . Eddy-current braking torque () makes steady speed , so total disc revolutions . Because shunt-coil copper resistance prevents from naturally lagging by a full , the copper lag-adjuster band adds a small phase-shifting flux so lags by exactly , ensuring accurate registration at all power factors.
An induction-type energy meter drives an aluminium disc with torque proportional to true power against eddy-current braking so disc revolutions integrate energy. The copper lag-adjuster band ensures the shunt flux lags supply voltage by exactly .
A single-phase energy meter makes revolutions in while supplying a purely resistive load drawing at (). Calculate the meter constant in .
Power and energy consumed in :
Meter constant :
Meter constant .
Describe the construction and working principle of a ferrodynamic-type frequency meter. Explain how it responds when the supply frequency rises above normal.
Construction: A laminated iron core of varying cross-section carries a fixed magnetizing coil at one end (connected across the AC supply) and a pivoted moving coil in series with a fixed capacitor (no control spring).
Working principle and response to rising frequency: Magnetizing flux induces an EMF in the moving coil lagging by . Moving-coil current leads or lags by angle depending on vs . Torque vanishes only at electrical resonance (). If supply frequency rises, falls so ; the resulting torque moves the pivoted coil away from the magnetizing coil where the core cross-section and are smaller until is restored at the higher frequency mark.
The ferrodynamic frequency meter balances inductive and capacitive reactance () along a tapered iron core. When frequency rises, drops and torque shifts the moving coil away from the magnetizing coil to lower until resonance is restored.
Show that the average deflecting torque of a dynamometer-type wattmeter on an AC supply is proportional to true power . If a wattmeter with current-coil resistance is connected so that the pressure coil is on the supply side of the current coil, find the error and percentage error when supplying at and power factor.
AC average torque proof: With and , instantaneous torque is proportional to . Averaging over one period gives:
True power, current-coil loss error, and percentage error:
When the pressure coil is on the supply side, the wattmeter measures load power plus current-coil copper loss :
. True load power is , current-coil error is , and percentage error is .