Open in the Padhaiko app1.1 Characteristics of various network elements
A network is an interconnection of elements. Before writing equations we must know what each element can and cannot do.
Classification of Network Elements
- Active element: can deliver energy to the network (independent or dependent voltage and current sources, op-amps, transistors).
- Passive element: only absorbs or stores energy (resistor , inductor , capacitor ).
- Linear element: obeys superposition and homogeneity, so its – relation is a straight line through the origin (, , ). A diode or a saturating iron-core inductor is non-linear.
- Bilateral element: has the same – behaviour for either direction of current (R, L, C). A diode is unilateral.
- Lumped element: its size is negligible compared with the wavelength, so voltage and current are defined at its terminals. A long transmission line is distributed.
- Time-invariant element: its value does not change with time.
| Element | Voltage–current relation | Energy | Continuity rule | Behaviour at and at DC steady state |
|---|---|---|---|---|
| Resistor | dissipates | none, responds instantly | always | |
| Inductor | stores | steady state: short circuit | ||
| Capacitor | stores | steady state: open circuit | ||
| Independent source | fixed or fixed | supplies | none | value set by designer |
| Dependent source | or proportional to another or | supplies | none | VCVS, CCVS, VCCS, CCCS |
1.2 Nodal analysis with dependent and independent sources
Nodal Analysis
Choose one reference node (ground). For each of the remaining nodes write KCL in terms of node voltages, using for each resistor. The result is simultaneous equations.
- A dependent source is written like an independent source, then its controlling variable is expressed in node voltages. This gives one extra relation and adds terms to the matrix.
- A voltage source between two non-reference nodes forms a supernode: write one KCL for the pair and add the constraint .
1.3 Mesh analysis with dependent and independent sources
Mesh Analysis
For a planar network with branches and nodes there are meshes. Assign a clockwise current to each mesh and write KVL around it. Resistor shared by two meshes carries the difference of the mesh currents.
- A current source on the edge of one mesh fixes that mesh current. A current source shared by two meshes forms a supermesh.
- A dependent source is treated as a normal source, and its controlling quantity is rewritten using mesh currents.
| Aspect | Nodal analysis | Mesh analysis |
|---|---|---|
| Law used | KCL at nodes | KVL around meshes |
| Unknowns | node voltages, of them | mesh currents, of them |
| Easiest when | many parallel branches and current sources | many series elements and voltage sources |
| Special case | voltage source gives a supernode | current source gives a supermesh |
| Applies to | any circuit | planar circuits only |
1.4 Application of matrix method in network analysis
Matrix Form of Nodal and Mesh Equations
Writing the equations in matrix form lets any circuit be solved by a standard routine.
- Nodal: is the sum of conductances connected to node (always positive). is minus the conductance between nodes and . is the net source current entering node .
- Mesh: is the sum of resistances in mesh . is minus the resistance shared by meshes and . is the net source voltage rise in the direction of .
Solve by Cramer's rule: , where is with column replaced by the right-hand side. For a system, .
1.1
A current source of enters node 1. Node 1 is connected to ground through and to node 2 through . Node 2 is connected to ground through . A dependent current source (amperes, with in volts) is also connected from ground into node 2. Find and by nodal analysis in matrix form.
KCL at each node. Currents leaving the node equal currents entering it.
The dependent current is already expressed in a node voltage, so no extra equation is needed.
Matrix form. Collect coefficients (the dependent term moves to the left side and makes the matrix unsymmetrical):
Cramer's rule.
Check at node 1: . Check at node 2: .
and .
1.2
Mesh 1 contains a source, a resistor and a resistor shared with mesh 2. Mesh 2 contains the shared , a resistor and a dependent voltage source (volts) which opposes . Both mesh currents are clockwise. Find and .
KVL for each mesh.
The controlling current is already a mesh current. The second equation simplifies to .
Matrix and solution.
and .
1.5 Procedure of evaluating initial conditions
A switching operation at changes a circuit suddenly. The currents and voltages just after the switch, at , are the initial conditions of the transient. Time is the instant just before the switch.
Procedure for Initial Conditions
- Draw the circuit for and find the steady state (for DC: inductors are short circuits, capacitors are open circuits). Get and .
- Use continuity: and . Energy cannot change instantly, so these two quantities cannot jump.
- Draw the circuit for after the switch. Replace each inductor by a current source and each capacitor by a voltage source .
- Solve this resistive circuit for every other current and voltage at (these may jump).
| Element | Condition before switching | Equivalent at |
|---|---|---|
| Inductor | open circuit | |
| Inductor | current source | |
| Capacitor | short circuit | |
| Capacitor | voltage source |
1.6 Initial values of derivatives
The classical method of Chapter 2 needs and at as well.
Initial Derivatives
Use the element equations at :
Find and from the circuit (KVL and KCL). Higher derivatives follow by differentiating the loop or node equation and substituting the lower-order values.
1.7 Initial condition in the case of R-L-C network
Second-Order (R-L-C) Initial Conditions
A series R-L-C circuit has two energy stores, so two conditions are needed: and . A second-order equation also needs , found from KVL at :
For the source-free or DC equation , differentiate KVL once to get .
1.3
A source feeds in series with and the parallel combination of and . The circuit has been in steady state for a long time. At the switch removes the source and (the loop , , remains). Find , , and at .
Steady state for . The inductor is a short and the capacitor is open:
Continuity. and .
Circuit at . The source is gone, so KVL around the loop gives :
KCL at the parallel node: , hence .
, , , .
Exercises
Practice Exercises: Transients in Electric Circuit
Classify each element as active or passive, linear or non-linear, bilateral or unilateral: (a) resistor, (b) diode, (c) VCCS, (d) iron-core inductor that saturates. State what continuity rule applies to an inductor and a capacitor at a switching instant.
Classification. (a) resistor: passive, linear, bilateral. (b) diode: passive, non-linear, unilateral. (c) VCCS: active, linear, unilateral (its output does not affect the input). (d) saturating inductor: passive, non-linear, bilateral.
Continuity. Stored energy and cannot change in zero time without infinite power, so and .
Resistor passive linear bilateral; diode passive non-linear unilateral; VCCS active linear unilateral; saturating inductor passive non-linear bilateral. and are continuous.
Use nodal analysis to find and . A source enters node 1. Node 1 to ground: . Node 1 to node 2: . Node 2 to ground: . A dependent current source leaves node 2 towards ground.
Equations.
Matrix form.
Solve. .
, .
Write the mesh equations in matrix form for a three-mesh network and solve. Mesh 1: source, own, shared with mesh 2. Mesh 2: shared with mesh 1, own, shared with mesh 3. Mesh 3: shared with mesh 2, own, a source opposing .
Impedance matrix. The diagonal terms are the total resistance in each mesh:
Solve. . , so . , so . , so .
, , .
A source feeds in series with and (all in series). The switch has been closed for a long time and opens at so that the source and are removed and , form a closed loop. Find , and at .
Before opening. The inductor is a short, so the current is limited by and in series: .
At . flows through , which gives . KVL around the loop: .
, , .
A series R-L-C circuit has , , and is initially relaxed. A DC source is switched on at . Find , , and at .
Continuity. Relaxed means and , so and .
First derivative. KVL: . At , , so .
Second derivative. Differentiate KVL (the source is constant): . At :
, , , .