PadhaikoAll subjects

AC Circuit Analysis

Fundamental of Electrical and Electronics Engineering (ENEX 101)

Open in the Padhaiko app

3.1 Single-phase AC circuit analysis

Single-phase AC circuit analysis studies linear networks excited by sinusoidal voltages and currents of a single constant angular frequency . Because derivatives and integrals of sinusoids at frequency remain sinusoids of the same frequency, steady-state analysis reduces differential equations to algebraic equations using complex numbers and phasors.

3.1.1 Series, parallel and network circuits with sinusoidal excitations

In a linear circuit driven by a sinusoidal source , every steady-state branch voltage and current is also sinusoidal at the same angular frequency , differing only in amplitude and phase angle.

3.1.2 The concept of complex impedance and admittance

Definition

Complex Impedance (Z) and Admittance (Y)

  1. Complex Impedance (, Ohm ): The ratio of the phasor voltage across a passive two-terminal network to the phasor current entering it in the sinusoidal steady state:

where:

  1. Complex Admittance (, Siemens ): The reciprocal of complex impedance, useful for parallel circuits:

where is conductance () and is susceptance ().

3.1.3 Sinusoidal excitation of inductive and capacitive reactance and complex impedance

Applying a sinusoidal current or voltage to pure , , and elements yields their steady-state reactances and complex impedances:

  1. Pure Resistor (): . Voltage and current are in phase ():
  1. Pure Inductor (): . Voltage leads current by (current lags voltage by ):
  1. Pure Capacitor (): . Current leads voltage by (voltage lags current by ):
Impedance, Admittance, and Phase Relations for R, L, and C
ElementReactance ()Complex Impedance Complex Admittance Voltage–Current Phase Relation
Resistor () and are in phase ()
Inductor () leads by ( lags )
Capacitor () lags by ( leads )

3.1.4 Concept of time phase differences between various sinusoidal quantities

Consider two sinusoidal quantities of the same frequency :

The phase difference between them is (in degrees or radians), corresponding to a time shift :

3.1.5 Phasor concept and phasor representation of AC quantities

Definition

Phasor Representation (Euler's Identity)

A phasor is a complex number that represents the RMS magnitude (or peak amplitude, depending on convention) and phase angle of a sinusoidal waveform of fixed frequency . Using Euler's formula , a sinusoid (or in sine reference ) is mapped to the time-invariant RMS phasor:

(Both and conventions yield identical phasor circuit results as long as all sources use the same reference function. Note that and in the phasor domain.)

Conversion between polar () and rectangular () forms:

3.1.6 Transformed impedances and network reduction

In the phasor (frequency) domain, every resistor, inductor, and capacitor is replaced by its transformed complex impedance (, , ) and every sinusoidal source by its phasor ( or ). Network reduction follows the exact algebraic rules of DC circuits:

3.1.7 Real, reactive and apparent power concepts

Definition

Real (Active), Reactive, and Apparent Power

Let the RMS phasor voltage across a load be and the RMS phasor current entering it be , with phase angle (the impedance angle of the load):

  1. Apparent Power (, Volt-Amperes ): Product of RMS voltage and RMS current:
  1. Real / Active / True Power (, Watts ): Average power actually consumed or converted into heat/mechanical work:
  1. Reactive Power (, Volt-Amperes Reactive ): Power oscillating back and forth between the source and energy-storing elements ( or ), doing zero net average work:
  1. Complex Power () and Power Factor ():

3.2 Three phase AC circuit

Industrial power generation, transmission, and heavy motors predominantly use balanced three-phase systems because they deliver constant instantaneous total power, transmit more power per kilogram of conductor than single-phase lines, and produce a rotating magnetic field naturally in motors.

3.2.1 Generation of three phase voltage

When three identical armature coils ( or ) are mounted mechanically apart on a stationary stator and a magnetic rotor spins at uniform angular speed , three sinusoidal voltages of equal magnitude and equal frequency are induced, displaced mutually in time phase by ():

In RMS phasor form (positive phase sequence ):

At every instant, the sum of three balanced phase voltages is identically zero:

3.2.2 Wye and delta connection

A three-phase source or load can be interconnected in Wye (Star, Y)—joining three ends at a common neutral point —or in Delta ()—connecting the three phase windings in a closed triangle with no neutral.

Theorem

Voltage, Current, and Power Relations in Balanced Y and Δ Systems

Let and denote line-to-line voltage and line current, and let and denote phase voltage and phase current across each phase impedance :

  1. Balanced Star (Wye, Y) Connection:
    • Line current equals phase current: .
    • Line voltage leads corresponding phase voltage by with magnitude times larger:
  1. Balanced Delta () Connection:
    • Line voltage equals phase voltage: .
    • Line current lags corresponding phase current by with magnitude times larger:
  1. Three-Phase Power (Identical Formula for Both Balanced Y and ):

(For the same three phase impedances connected across the same line voltage , the Delta connection draws times the line current and times the power of the Star connection: .)

Comparison of Balanced Star (Y) and Delta (Δ) Connections
ParameterStar (Wye, Y) ConnectionDelta () Connection
Voltage Relation ( leads by )
Current Relation ( lags by )
Neutral WireAvailable (-wire system possible; if balanced)Not available (-wire system only)
Total Real Power ()
Power Ratio (Same )

Worked Out Examples

Example 3.1

3.1

A series circuit has , , and , and is excited by an AC voltage . Calculate:

  1. , , and the total complex impedance .
  2. The RMS current phasor and the time-domain current .
  3. The power factor, real power , reactive power , and apparent power .

Reactances and complex impedance: From , the angular frequency is and the RMS source phasor is .

Converting to polar form:

RMS current phasor and time-domain current:

Converting back to the time domain ():

Power factor, real power, reactive power, and apparent power: Since , the circuit is inductive and current lags voltage by :

Answer:
  1. , , .
  2. , .
  3. , , , .
Example 3.2

3.2

A (RMS) source feeds a series resistor connected to a parallel combination of Branch 1 () and Branch 2 (). Using admittance and transformed impedance reduction, find:

  1. The total parallel admittance and equivalent parallel impedance .
  2. The total source current and branch currents .
  3. The total real power drawn from the source.

Parallel admittance and impedance : Compute the admittance of each branch by rationalizing the complex denominators:

Adding the parallel admittances:

Thus, the parallel combination reduces to a purely resistive equivalent impedance:

Total impedance, source current, and branch currents: Adding the series resistor :

Source current:

The voltage across the parallel combination is , giving branch currents:

(KCL check: .)

Total real power drawn from the source: Since is in phase with (, unity power factor):

Answer:
  1. , .
  2. , , .
  3. ().
Example 3.3

3.3

Three identical coils, each with resistance and inductive reactance , are connected across a balanced (line-to-line), , three-phase supply. Calculate the phase voltage, phase current, line current, power factor, and total real power when the coils are connected in:

  1. Star (Wye, Y)
  2. Delta ()

Phase impedance and power factor of each coil:

Case 1: Star (Y) Connection:

  • Phase voltage:
  • Phase and line current:
  • Total three-phase real power:

Case 2: Delta () Connection:

  • Phase voltage: .
  • Phase current:
  • Line current:
  • Total three-phase real power:
Answer:
  1. Star (Y): , , , .
  2. Delta (): , , , , .

Exercises

Practice Exercises — AC Circuit Analysis

Question 1

Define complex impedance and complex admittance . Explain the physical meaning of real power (), reactive power (), apparent power (), and power factor () in a single-phase AC circuit.

Complex Impedance and Admittance:

  • Complex Impedance () measures total opposition to sinusoidal current, combining dissipative resistance and energy-storing reactance .
  • Complex Admittance () measures ease of sinusoidal current flow, combining conductance and susceptance .

Real, Reactive, Apparent Power, and Power Factor:

  • Real Power (, ): Net average power consumed in resistors or converted to useful work.
  • Reactive Power (, ): Power oscillating between the source and magnetic/electric fields of and with zero net average energy transfer.
  • Apparent Power (, ): Product of RMS voltage and current that sets equipment ratings (transformers, cables, generators).
  • Power Factor (): Fraction of apparent power converted to real power (; lagging for inductive loads, leading for capacitive loads).
Answer:

is the phasor ratio and . Real power does useful work; reactive power sustains alternating fields; apparent power sizes equipment; and .

Question 2

Two sinusoidal currents are given by and , while a voltage is .

  1. Find the phase difference and time difference (in ) between and , stating which leads.
  2. Express as a single sine function and find its RMS phasor.

Phase and time difference between and : The phase angles are and , so:

Thus leads by . At (), the time lead is:

Combining : Using where :

Hence , with RMS phasor:

Answer:
  1. leads by ().
  2. , RMS phasor .
Question 3

A series circuit has , , and connected across a variable-frequency (RMS) AC supply. Find:

  1. The resonant frequency .
  2. The circuit current and power factor at resonance.
  3. The voltage across the inductor and across the capacitor at resonance.

Resonant frequency : At series resonance, :

Current, power factor, and reactive voltages at resonance: At , , so :

The RMS voltages across and (equal in magnitude, out of phase) are:

Answer:
  1. .
  2. , (unity).
  3. (equal and opposite, canceling each other).
Question 4

Three branches are connected in parallel across a (RMS) single-phase AC supply: a resistor , an inductive reactance , and a capacitive reactance . Find:

  1. The total admittance and total supply current .
  2. The overall power factor, real power , and net reactive power .

Total admittance and supply current:

Converting to polar form:

Power factor, real power, and net reactive power:

Answer:
  1. , .
  2. , , .
Question 5

A balanced three-phase star-connected industrial load draws at lagging power factor from a (line-to-line), three-phase supply. Calculate:

  1. The line current and phase current .
  2. The apparent power (in ) and reactive power (in ).
  3. The per-phase impedance magnitude and resistance .

Line and phase current: Using :

For a star-connected load, .

Apparent power and reactive power :

Since (lagging):

Per-phase impedance and resistance: Phase voltage is :

Answer:
  1. .
  2. , .
  3. , .
← Average and RMS ValuesDiodes →