Green Energy Sources

Energy, Environment and Social Engineering (ENEX 417)

Open in the Padhaiko app

3.1 Solar Energy

3.1.1 Solar Radiation

The Sun radiates electromagnetic energy across ultraviolet, visible, and near-infrared wavelengths (). Outside Earth's atmosphere at the mean Sun–Earth distance (), the irradiance on a normal surface is the Solar Constant:

As solar radiation passes through the atmosphere, Rayleigh scattering, aerosol scattering, and absorption by , , and attenuate it into components:

Definition

Solar Radiation Components and Irradiance Metrics

where is direct normal irradiance and is the solar zenith angle.


3.1.2 Solar Thermal Energy

Solar thermal systems capture solar radiation as sensible or latent heat using a solar collector and transfer it to a working fluid (water, air, glycol, or thermal oil).

  1. Non-Concentrating (Low-to-Medium Temperature, ) Collectors:
    • Flat-Plate Collector (FPC): Absorber plate with dark selective coating, copper/aluminum riser tubes, transparent glass cover (trapping infrared via the greenhouse effect), and rear thermal insulation. Common for domestic solar water heaters.
    • Evacuated Tube Collector (ETC): Concentric glass tubes with a vacuum annulus that suppresses convective and conductive heat loss—performing far better in cold, windy, or high-altitude climates (such as Himalayan regions).
  2. Concentrating (High Temperature, ) Collectors (CSP):
    • Parabolic Trough, Solar Power Tower (Heliostats + Central Receiver), and Parabolic Dish systems track the Sun and focus direct beam radiation onto a small absorber to drive steam/gas turbines for electricity or industrial process heat.

Collector Thermal Efficiency

The useful thermal power absorbed by a fluid of mass flow rate and specific heat rising from to is:

Instantaneous collector efficiency for aperture area and incident irradiance is:


3.1.3 Solar Photovoltaic(PV)

Solar Photovoltaics (PV) directly convert sunlight into DC electricity via the photovoltaic effect in semiconductor junctions (most commonly monocrystalline or polycrystalline silicon, or thin-film / ).


3.2 Hydropower

3.2.1 Water sources and Power

Hydropower converts the gravitational potential energy and kinetic energy of flowing water (rivers, streams, glacial snowmelt, or impounded reservoirs) into mechanical shaft rotation and then electrical power.

Definition

Hydropower Equation

For volumetric discharge (), water density , gravitational acceleration , and net hydraulic head ():

where is turbine efficiency () and is generator efficiency ().


3.2.2 Water Turbines and Hydroelectric Plants

Hydroelectric Plant Configurations

  1. Run-of-River (RoR) Plants: Divert river flow through an intake, desilting basin, headrace canal/tunnel, forebay, and penstock to the powerhouse with minimal or daily pondage. Common in Nepal's steep Himalayan rivers; output varies strongly between monsoon and dry seasons.
  2. Storage (Reservoir) Plants: Impound water behind a dam to regulate seasonal flow, provide firm peaking power, and support flood control/irrigation.
  3. Pumped-Storage Hydropower (PSH): Reversible pump-turbines pump water to an upper reservoir during off-peak/solar surplus hours and generate during peak demand—acting as grid-scale energy storage.

Water Turbines: Impulse vs. Reaction

AspectImpulse Turbines (e.g., Pelton, Turgo, Crossflow)Reaction Turbines (e.g., Francis, Kaplan)
Energy Conversion at RunnerEntire pressure head converts to kinetic energy in a nozzle jet at atmospheric pressureWater enters runner under pressure; both pressure and kinetic energy drop across blades
Operating Head & FlowHigh head ( for Pelton), low flowMedium head (, Francis); low head, high flow (, Kaplan)
Casing & Draft TubeOpen casing at atmospheric pressure; no draft tube requiredAirtight spiral casing and submerged draft tube to recover exit kinetic head
Part-Load EfficiencyHigh efficiency across wide flow variations (needle spear valve / multi-jet control)Francis efficiency drops sharply at low part-load; Kaplan uses adjustable pitch blades to stay efficient

3.2.3 Hydropower Plant Classification(pico, micro, small, medium, large)

Hydropower installations are classified by installed electrical capacity. International (IEA/UNIDO) and Nepal's Electricity/Hydropower Development Policy brackets follow these standard ranges:

Classification of Hydropower Plants by Capacity
CategoryStandard International Capacity RangeTypical Application & Turbine
Pico-hydroIndividual households, small rural clusters; Pelton/Crossflow/propeller
Micro-hydroIsolated village mini-grids, rural agro-processing; Pelton, Crossflow
Mini-hydro (often grouped with Small)District mini-grids, local grid feed-in
Small hydro (Nepal policy: up to )Regional distribution feeders, RoR IPPs
Medium hydro (Nepal: )National grid base/peaking stations
Large hydroMajor national & cross-border transmission generation

3.3 Wind Energy

3.3.1 Availability of Wind Energy Sources

Wind originates from uneven solar heating of Earth's surface and atmosphere combined with the Coriolis effect. Assessing a wind site requires multi-year anemometer measurements (commonly modeled by a Weibull wind-speed distribution), because wind power scales with the cube of wind speed.

Definition

Wind Power Equation and Betz Limit

For an air mass of density ( at sea level, ) passing perpendicular to a rotor swept area at undisturbed wind speed :

where modern commercial turbines achieve .

Wind speed also increases with hub height due to surface roughness (wind shear), often modeled by the power law: , where over open terrain.


3.3.2 Wind turbines, wind parks and power control

Turbine Types: HAWT vs. VAWT

Operating Regimes and Power Control

A wind turbine's power curve has three critical wind speeds:

  1. Cut-in Speed (): Minimum wind to overcome drivetrain friction and start generating.
  2. Rated Speed (): Wind speed at which rated generator power is reached.
  3. Cut-out Speed (): High-wind shutdown threshold where blades feather and brakes engage to prevent structural damage.

Between and , power is capped using:

Wind Parks (Wind Farms)

When clustering turbines into a wind park, downstream turbines experience wake effects (reduced wind speed and higher turbulence). Standard engineering layout spaces turbines rotor diameters () apart along the prevailing wind direction and apart crosswind, integrating collector substations, SCADA monitoring, and reactive-power/voltage ride-through hardware.


3.4 Hydrogen Energy and Fuel Cell

3.4.1 Hydrogen energy, production and storage

Hydrogen () is a versatile energy carrier (not a primary geological source) with very high gravimetric energy density (, ), though low volumetric density at ambient conditions.

Production Pathways ("Hydrogen Color Code")

Hydrogen Storage Methods

  1. Compressed Gas Storage: High-pressure Type III/IV composite cylinders at (standard for FCEVs).
  2. Cryogenic Liquid Storage (): Cooled to (); high volumetric density but energy-intensive liquefaction ( of energy) and boil-off losses.
  3. Solid-State / Metal Hydrides: Reversible chemical absorption in metal alloys (e.g., , ) at moderate pressures; compact and inherently safer, though heavier.

3.4.2 Basics of electrochemistry

A fuel cell is an electrochemical device that converts the chemical energy of a fuel (hydrogen) and an oxidant (oxygen/air) directly into DC electricity, water, and heat—bypassing combustion and the Carnot heat-engine efficiency limit.

Definition

Fuel Cell Thermodynamics and Efficiency

where and Faraday's constant . At for liquid water product ():


3.4.3 Polymer membrane electrolyte(PEM) fuel cells

A Proton Exchange Membrane / Polymer Electrolyte Membrane (PEM) Fuel Cell uses a solid hydrated fluoropolymer membrane (typically Nafion) that conducts protons while blocking electrons and gases:


3.4.4 Solid oxide fuel cells(SOFCs)

A Solid Oxide Fuel Cell (SOFC) uses a dense ceramic oxide electrolyte, most commonly Yttria-Stabilized Zirconia (YSZ), which conducts oxygen ions () at high temperatures ():

AspectPEM Fuel Cell (PEMFC)Solid Oxide Fuel Cell (SOFC)
Electrolyte & Charge CarrierPolymer membrane (Nafion); conducts Ceramic YSZ; conducts
Operating TemperatureLow ()High ()
Catalyst & Fuel PurityPlatinum (); requires ultra-pure (-sensitive)Non-precious Ni-YSZ cermet; tolerates , syngas, biogas, natural gas
Startup & Primary UseFast startup (seconds); EVs, backup UPS, portable powerSlow thermal warmup; stationary Combined Heat & Power (CHP), data centers

Worked Examples

Example 3.1

3.1

A micro-hydro plant operates with a gross head of and penstock friction/bend losses of at a design flow rate (, ). If the Pelton turbine efficiency is and generator efficiency is , calculate:

  1. Net hydraulic head ().
  2. Theoretical hydraulic power () in .
  3. Net electrical power output () in and its plant classification.

1. Net Hydraulic Head:

2. Theoretical Hydraulic Power:

3. Electrical Power Output and Classification:

Since lies between and , it falls in the mini-hydro bracket (just above the micro-hydro ceiling).

Answer:
  1. Net head:
  2. Theoretical hydraulic power:
  3. Electrical output: (mini-hydro classification)
Example 3.2

3.2

A horizontal-axis wind turbine has a rotor diameter operating at air density and wind speed . Its aerodynamic power coefficient is and mechanical-electrical drive efficiency is . Determine:

  1. Rotor swept area ().
  2. Available wind power () in .
  3. Maximum theoretical Betz power () in .
  4. Actual electrical power output () in .

1. Rotor Swept Area (): With radius :

2. Available Wind Power ():

3. Maximum Betz Power ():

4. Actual Electrical Power Output ():

Answer:
  1. Swept area:
  2. Available wind power:
  3. Betz theoretical maximum:
  4. Actual electrical output:
Example 3.3

3.3

  1. Solar Thermal Collector: A flat-plate collector of area receives irradiance and heats water flowing at from to (). Calculate the useful heat gain and collector efficiency .
  2. Fuel Cell Potential: Given for a PEM fuel cell (, ), verify the standard reversible cell voltage .

1. Useful Thermal Gain and Collector Efficiency:

Incident solar power .

2. Standard Reversible Cell Voltage:

Answer:
  1. Useful heat gain: ; collector efficiency:
  2. Standard reversible cell voltage:

Exercises

Practice Exercises — Green Energy Sources

Question 1

Define Solar Constant, Direct Radiation, Diffuse Radiation, Air Mass (), and Peak Sun Hours (). Why does an evacuated tube solar thermal collector outperform a flat-plate collector in cold Himalayan climates?

Solar Radiation Definitions:

  • Solar Constant (): Extraterrestrial solar irradiance on a surface normal to the Sun's rays at .
  • Direct Radiation: Unscattered beam radiation arriving directly from the solar disc.
  • Diffuse Radiation: Solar radiation scattered by atmospheric molecules, clouds, and dust arriving from the full sky dome.
  • Air Mass (): Relative atmospheric path length (); is standard for PV rating.
  • Peak Sun Hours (): Daily solar insolation in divided by .

Evacuated Tube vs. Flat-Plate in Cold Climates: A flat-plate collector loses heat to cold ambient air and wind by conduction and convection across its air gap. An evacuated tube collector surrounds the absorber with a vacuum annulus, eliminating convective and conductive heat loss so high thermal efficiency is maintained even at sub-zero ambient temperatures.

Answer:

The Solar Constant is ; direct radiation travels straight from the Sun while diffuse radiation is scattered by the sky; Air Mass measures atmospheric path length; and PSH equals daily insolation. Evacuated tube collectors outperform flat-plate collectors in cold climates because their vacuum gap suppresses convective and conductive heat loss.

Question 2

A run-of-river hydroelectric station has a design flow , net head , and overall plant efficiency (, ). Calculate the electrical power output in and select an appropriate turbine type and plant classification.

Computing Electrical Power Output:

Turbine Selection and Classification: With and , a Francis turbine (medium-to-high head reaction turbine) or a multi-jet Pelton turbine is suitable. At , the station is classified as a small hydropower plant ( international; in Nepal).

Answer:

Electrical power output: ; suitable turbine: Francis (or multi-jet Pelton); classification: Small hydropower plant.

Question 3

A wind turbine produces at a wind speed of . Assuming constant overall efficiency () and air density, what electrical power will it produce when wind speed increases to (still below rated speed)? Explain cut-in, rated, and cut-out wind speeds.

Cubic Scaling of Wind Power: Since for fixed swept area, air density, and efficiency:

Characteristic Wind Speeds:

  • Cut-in speed (): Minimum wind speed where rotor torque overcomes friction and generation begins.
  • Rated speed (): Wind speed at which the turbine reaches full nameplate electrical output; pitch/stall control caps power above this speed.
  • Cut-out speed (): Maximum safe operating wind speed above which the turbine feathers blades and shuts down to avoid mechanical damage.
Answer:

At , the turbine produces (power scales as ). Cut-in is the startup threshold, rated is where full capacity is reached, and cut-out is the storm-safety shutdown speed.

Question 4

Compare Grey, Blue, and Green hydrogen production methods, and evaluate compressed gas, liquid cryogenic, and metal hydride hydrogen storage techniques.

Hydrogen Production Colors:

  • Grey : Produced via Steam Methane Reforming (SMR) of natural gas; emits directly to the atmosphere.
  • Blue : SMR coupled with Carbon Capture and Storage (CCS) to sequester most process .
  • Green : Produced by splitting water via electrolysis powered solely by renewable energy (hydro, solar, wind) with zero operational carbon emissions.

Comparison of Storage Techniques:

  • Compressed Gas (): Mature and fast-refueling in composite tanks, but requires compression energy and bulky high-pressure vessels.
  • Cryogenic Liquid (): High energy density per volume, but liquefaction consumes of energy and suffers boil-off.
  • Metal Hydrides: Stores hydrogen safely at low pressure inside metal alloy lattices, at the cost of higher tank weight and thermal management for desorption.
Answer:

Grey uses SMR with release, Blue adds CCS, and Green uses renewable-powered water electrolysis. Storage relies on high-pressure composite tanks (), cryogenic liquefaction (), or solid-state metal hydrides, trading off volume, weight, energy penalty, and safety.

Question 5

Compare PEM Fuel Cells (PEMFC) and Solid Oxide Fuel Cells (SOFC) in terms of electrolyte, charge carrier, operating temperature, catalyst/fuel tolerance, and engineering applications.

Key Technical Comparison:

  • PEMFC: Uses a solid polymer membrane (Nafion) conducting protons at with a catalyst. It starts up rapidly and offers high power density for transport and backup UPS, but requires ultra-pure to avoid catalyst poisoning.
  • SOFC: Uses a ceramic YSZ electrolyte conducting ions at with non-precious Ni-cermet electrodes. It tolerates , natural gas, and biogas via internal reforming and provides high-grade waste heat for Combined Heat and Power (CHP), though thermal cycling is slow.
Answer:

PEMFCs conduct through a polymer membrane at using catalysts—suiting vehicles and fast-response backup with pure . SOFCs conduct through ceramic YSZ at , offering fuel flexibility and high-efficiency stationary CHP.

← Energy BasicsEnergy Storage →