PadhaikoAll subjects

Two-Port Parameters of Network

Electrical Circuits and Machines (ENEE 154)

Open in the Padhaiko app

5.1 Definitions of two-port networks

Definition

Two-Port Network

A two-port is a network with four terminals grouped as an input port (voltage , current ) and an output port (voltage , current ). The current entering one terminal of a port equals the current leaving the other. Standard references: both and are taken into the network. The network must be linear, contain no independent sources and have no initial stored energy. Two of the four variables are independent, so any pair can be expressed through the other pair using two-port parameters.

5.2 Parameters of two-port networks

5.2.1 Open circuit impedance parameters

Definition

Z (Open-Circuit Impedance) Parameters

(input impedance, output open), , , . Determinant .

5.2.2 Short circuit admittance parameters

Definition

Y (Short-Circuit Admittance) Parameters

, , , . Also .

5.2.3 Transmission line parameters

Definition

ABCD (Transmission) Parameters

Input quantities in terms of output, with so that the output current flows out of the port:

, , , . Input impedance with load : .

5.2.4 Inverse transmission line parameters

Definition

Inverse Transmission Parameters

Output quantities in terms of input:

The matrix is the inverse of the ABCD matrix.

5.2.5 Hybrid parameters

Definition

h (Hybrid) Parameters

(input impedance, ohm), (reverse voltage ratio), (forward current gain), (output admittance, siemens). These suit transistor models.

5.2.6 Inverse hybrid parameters

Definition

g (Inverse Hybrid) Parameters

The matrix is the inverse of the matrix.

5.3 Relationship and transformation between sets of parameters

Conversions from Z and Y Parameters
ToFrom From

5.4 Interconnection of two port networks

Interconnections and Which Parameters Add
ConnectionPortsRule
Series-seriesinputs in series, outputs in series
Parallel-parallelinputs in parallel, outputs in parallel
Cascadeoutput of A feeds input of B (ABCD, in that order)
Series-parallelinputs in series, outputs in parallel
Parallel-seriesinputs in parallel, outputs in series

5.5 Condition for reciprocity and symmetry

Reciprocity and Symmetry Conditions
ParametersReciprocal networkSymmetrical network
(and reciprocal)
ABCD

A reciprocal network gives the same ratio of response to excitation when source and response ports are exchanged. It holds for networks of , , and fails with dependent sources such as transistor models. A symmetrical network looks the same from both ports.

Example 5.1

5.1

A T-network has series arms (input side) and (output side) and a shunt arm . Find its , and ABCD parameters and check reciprocity.

Z parameters. Open the output (): and . Open the input: and .

Y parameters. , so , , .

ABCD. From the table: , , , .

Answer:

, , , , , , , .

Example 5.2

5.2

Two two-ports are cascaded. The first is a series resistor and the second a shunt resistor. Find the overall ABCD matrix, the open-circuit voltage ratio and the input impedance when the load is .

Individual matrices. Series : . Shunt : .

Cascade product.

Open-circuit ratio and . (check: and in a divider). With :

Direct check: .

Answer:

, , .

Example 5.3

5.3

A transistor has , , , and drives a load . Find the current gain, voltage gain and input impedance.

Load relation. . Substituting in :

Input impedance.

Voltage gain. With :

Answer:

, , .

Exercises

Practice Exercises: Two-Port Parameters

Question 1

State the conditions for reciprocity and symmetry in terms of , , ABCD and parameters, and the parameter set that adds for each of the five interconnections.

Conditions. : ; symmetry also . : , . ABCD: , . : , .

Connections. Series-series adds . Parallel-parallel adds . Cascade multiplies ABCD. Series-parallel adds . Parallel-series adds .

Answer:

As tabulated above.

Question 2

A -network has an input shunt admittance , a series admittance and an output shunt admittance . Find and then .

Y parameters. , , .

Z parameters. . , , .

Answer:

, .

Question 3

Given , , , find the parameters and check reciprocity.

Conversion. . , , , .

Reciprocity. , so the network is reciprocal.

Answer:

, , , ; reciprocal.

Question 4

Two networks with and (siemens) are connected in parallel. Find the combined and the open-circuit voltage ratio (output open).

Combined Y. Add elementwise: .

Open output. gives , so .

Answer:

, .

Question 5

A network has , , , . Show that it is reciprocal and symmetrical, find its parameters and the input impedance with a load.

Tests. (reciprocal) and (symmetrical).

Z parameters. , , , .

Input impedance. .

Answer:

Reciprocal and symmetrical; , ; .

← Network Transfer Function and Frequency ResponseMagnetic Circuit and Induction →