PadhaikoAll subjects

DC Machine

Electrical Circuits and Machines (ENEE 154)

Open in the Padhaiko app

8.1 Constructional details of DC machine

Definition

Parts of a DC Machine

8.2 Operating principle and EMF equation of DC generator

Definition

Generator Principle and EMF Equation

Principle: when a conductor cuts magnetic flux, an emf is induced (Faraday). The commutator rectifies the alternating emf of each coil.

Let be the flux per pole (Wb), the number of poles, the total armature conductors, the parallel paths and the speed in rpm. Flux cut per revolution is per conductor, and each revolution takes s, so the emf per conductor is . With conductors in series per path:

Lap winding: . Wave winding: . For a given machine .

8.3 Operating principle and torque equation of DC motor

Definition

Motor Principle and Torque Equation

Principle: a current-carrying conductor in a magnetic field experiences a force . The commutator keeps the force on all conductors in the same direction, so the armature turns.

Torque per conductor is . Summing over conductors with each gives

So . Armature power , where .

8.4 Types of DC machine

Types of DC Machine by Field Connection
TypeField connectionTerminal relations
Separately excitedfield from an independent source
Shuntfield in parallel with armature, high resistance, many turnsgenerator: ; motor:
Seriesfield in series with armature, low resistance, few turns
Compound (cumulative or differential)both shunt and series fields (long or short shunt)combination

8.5 Back EMF and its role in DC motor

Definition

Back EMF

The rotating armature conductors cut flux and develop an emf that opposes the supply voltage (Lenz's law). The armature current is

Role: is the self-regulating mechanism. If the load increases the speed falls, falls, rises and the torque grows until it meets the load. At starting so is very large, which is why a starter is needed. The mechanical power developed is , and it is the energy conversion link between electrical and mechanical sides. Speed follows .

8.6 Performance characteristics of DC motor

Characteristics of DC Motors
MotorSpeed–loadTorque–Typical use
Shuntnearly constant, falls to from no load to full load (straight line)lathes, fans, pumps
Seriesfalls sharply with load, dangerous at no load (races) below saturationtraction, cranes, hoists
Cumulative compoundfalls more than shunt, can start heavy loadsbetween shunt and seriespresses, shears, elevators

8.7 Starting of DC motor using 3-point starter

Definition

Three-Point Starter

Because at standstill, a variable starting resistance is placed in series with the armature: . As the motor accelerates, builds up and is cut out step by step.

The starter has three terminals: L (line), A (armature) and F (field). Features:

8.8 Speed control of DC motor (armature control, field control)

Definition

Speed Control

Since there are three ways to change speed:

For a constant load torque, is constant, so must rise when is reduced.

8.9 Losses and efficiency

Definition

Losses and Efficiency

Iron plus mechanical losses together are the rotational (stray) losses. For a generator the maximum efficiency occurs when the variable loss equals the constant loss (field plus rotational), so .

Example 8.1

8.1

A -pole generator has armature conductors, flux per pole and runs at . Find the generated emf for lap winding and for wave winding.

Lap winding ():

Wave winding ():

Wave winding gives twice the voltage with half the current capacity.

Answer:

(lap) and (wave).

Example 8.2

8.2

A shunt motor takes from the supply. and . Find the back emf, the armature power and the torque at .

Currents. so .

Back emf and power. and .

Torque. so .

Answer:

, , .

Example 8.3

8.3

For the motor of the previous example (running at with ) the shunt-field resistance is increased until the flux falls to of its value. The load torque is constant. Find the new speed.

New armature current. Constant torque with gives :

New back emf. .

Speed. Since :

Answer:

: weakening the field raises the speed.

Exercises

Practice Exercises: DC Machine

Question 1

Explain the role of back emf in a DC motor. Why is a starter required, and why does a 3-point starter have a no-volt coil? How is the speed of a shunt motor controlled above and below rated speed?

Back emf. opposes the supply, so . It automatically adjusts armature current to the load.

Starter. At standstill and is many times rated. A series starting resistance limits it. The no-volt coil, in series with the field, holds the handle at the final stud and returns it to OFF if the supply or field fails.

Speed control. Above rated: weaken the field (field control). Below rated: add resistance in the armature circuit (armature control), or lower the armature voltage.

Answer:

Field control for speeds above rated, armature control for speeds below rated.

Question 2

A shunt generator delivers at . and . Find the armature current and the generated emf.

Currents. , , so .

EMF. .

Answer:

, .

Question 3

A shunt motor has and rated armature current . Find the starting current without a starter, the starter resistance that limits the starting current to times rated, and the rated back emf.

No starter. , which is times rated.

With starter. Limit , so and .

Rated back emf. .

Answer:

; ; .

Question 4

A series motor has total resistance . At it runs at . Find the speed and the torque ratio when the current falls to (take flux proportional to current).

Back emfs. and .

Speed. and :

Torque. , so .

Answer:

; torque falls to .

Question 5

A shunt motor takes and has , and rotational losses of . Find the efficiency, and the armature current at which the efficiency is maximum.

Input and losses. . , . Armature copper , field , rotational ; total .

Efficiency. .

Maximum efficiency. Constant losses are . Maximum when , so .

Answer:

; maximum efficiency at .

← TransformersAC Motor →