PadhaikoAll subjects

Dimensioning

Engineering Drawing (ENME 101)

Open in the Padhaiko app

2.1 Fundamentals and techniques

An engineering drawing without dimensions only communicates shape; dimensioning supplies the exact sizes, feature positions, and manufacturing tolerances needed to build and inspect the part. Standard practice follows ISO 129-1 and BIS SP 46.

Elements of Dimensioning

Definition

Core Dimensioning Elements

  1. Projection (Extension) Lines: Continuous thin lines (Type B) extending perpendicularly from the feature outline slightly past the dimension line. Leave a visible 1 mm gap between the object outline and the start of the extension line, and extend the line 2–3 mm beyond the outermost dimension line.
  2. Dimension Lines: Continuous thin lines terminated by arrowheads (or oblique ticks/dots) showing the direction and extent of a measurement. Place the first dimension line 8–10 mm away from the object outline, and space parallel dimension lines uniformly 6–8 mm apart.
  3. Arrowheads: Closed, filled slender triangles drawn at both ends of a dimension line with a 3 : 1 length-to-width ratio (typically 3 mm long and 1 mm wide). All arrowheads on a drawing must be uniform in size.
  4. Leader Lines: Thin continuous lines drawn at an angle (30, 45, or 60 degrees—never horizontal or vertical) connecting a note or feature callout to the surface or edge. A leader ends in a dot if terminating inside a surface, an arrowhead if terminating on an outline/edge, and a short horizontal shoulder at the text end.
  5. Dimension Values and Standard Prefixes: Placed clearly with single-stroke lettering (normally 3.5 mm high). Standard ISO prefixes identify geometry concisely: DIA or symbol for diameter, R for radius, SR for spherical radius, SQ for square cross-section, C or 45 deg notation for chamfers, and t for plate thickness.
Geometry and Spacing of Dimension and Extension LinesText
              2-3 mm overhang
                  |                 |
       <==========|=== 45.00 =======|==========>   Dimension line (8-10 mm from edge)
                  |                 |
                  |  1 mm gap       |  1 mm gap
       +----------+-----------------+----------+
       |                                       |
       |              OBJECT                   |
       +---------------------------------------+

Fundamental Rules of Dimensioning


2.2 Size and location dimensioning, SI conversions

Every complex mechanical part is decomposed into simple geometric primitives (prisms, cylinders, cones, slots, holes). Dimensioning a part completely requires specifying both how big each feature is and where it sits.

AspectSize Dimension (S)Location Dimension (L)
PurposeDefines the physical magnitude of a geometric formFixes the position of a feature relative to another feature, centerline, or datum edge
Prism / BlockLength, width, height/thicknessOffset of stepped shoulder or slot from a reference face
Cylinder / HoleDiameter and axial length/depthDistance from the cylinder/hole centerline to two perpendicular datum edges (or center-to-center pitch)
Cone / PyramidBase diameter/side and altitude (or frustum diameters + height)Axis position relative to base datum
Chamfer / FilletLeg length x angle (e.g., 2 x 45 deg) or fillet radius RCorner already fixed by adjoining surfaces

SI Units and Standard Engineering Conversions

In mechanical engineering drawings under ISO and Institute of Engineering practice, the millimetre (mm) is the default linear unit. Individual numbers are written without the mm suffix, and a single title-block note states ALL DIMENSIONS ARE IN MM. Civil, surveying, and architectural drawings commonly use metres (m) or centimetres (cm) (with decimals such as 3.50 denoting 3.50 m).

Essential SI and Imperial Unit Conversions for Engineering Drawing
QuantityBase EquivalenceDerived Conversion
Metre / Millimetre1 m = 100 cm = 1000 mm1 km = 1000 m = 100000 cm = 1000000 mm
Decimetre1 m = 10 dm1 dm = 10 cm = 100 mm
Inch / Millimetre1 inch = 25.4 mm (exact)1 inch = 2.54 cm
Foot / Millimetre1 foot = 12 inches = 304.8 mm1 yard = 3 feet = 914.4 mm = 0.9144 m
Area (Square)1 sq m = 10000 sq cm1 sq m = 1000000 sq mm; 1 sq km = 1000000 sq m
Volume (Cubic)1 cu m = 1000 litres1 cu m = 1000000 cu cm = 1000000000 cu mm

2.3 Scales: Types and representative factor

Real engineering objects range from micro-machined watch gears to multi-kilometre highway bridges—neither fits conveniently on a drawing sheet at actual size. A drawing scale maintains exact geometric proportionality while shrinking or magnifying the representation.

Representative Fraction (RF)

Definition

Representative Fraction (RF) and Length of Scale (LOS)

The Representative Fraction (RF) is the dimensionless ratio of the linear dimension of an element on the drawing to the true linear dimension of the same element on the actual object, both expressed in the same unit:

When constructing a graphical scale on a sheet to read up to a specified Maximum Length (M_max), the physical Length of Scale (LOS) drawn on paper is:

Types of Engineering Scales

  1. Plain Scale: Consists of a line divided into a suitable number of equal main (primary) parts, with the first (leftmost) main part further subdivided into smaller secondary divisions (typically 10). A plain scale measures two consecutive units (e.g., metres and decimetres, or centimetres and millimetres) or one unit and its tenths.
  2. Diagonal Scale: Extends a plain scale to read three consecutive units (e.g., metres, decimetres, and centimetres) or precision to 0.01 of a main unit without crowding tiny tick marks. It relies on similar triangles: if a secondary subdivision of width d is connected diagonally across N equally spaced horizontal parallel lines, the horizontal intercept at level k equals (k / N) x d.
  3. Vernier Scale: Uses two graduated scales—a Main Scale and a short sliding/auxiliary Vernier Scale—where n vernier divisions equal either (n - 1) main divisions (Direct/Forward Vernier) or (n + 1) main divisions (Retrograde/Backward Vernier). Its Least Count (LC) is 1 main division / n.
  4. Comparative Scales: Two scales sharing the exact same RF placed back-to-back or side-by-side to read two different unit systems simultaneously (for instance, kilometres vs. miles, or millimetres vs. inches).
  5. Scale of Chords: A specialized graphical scale used to measure or lay off angles without a protractor. Along a baseline AB of arbitrary radius R, a quadrant arc is divided into 10-degree (or 5-degree) intervals, and chord distances 2 R sin(theta / 2) from A are transferred to the horizontal line.

2.4 Use of scales, measurement units, reducing and enlarging drawings

Depending on whether the drawn size equals, shrinks, or magnifies the physical part, ISO 5455 classifies scales into three categories:

Standard ISO 5455 Scale Designations
CategoryRF ConditionStandard ISO RatiosTypical Engineering Applications
Full-Size ScaleRF = 11 : 1Hand tools, medium machine brackets, jigs, fixtures
Reducing ScaleRF < 11 : 2, 1 : 5, 1 : 10, 1 : 20, 1 : 50, 1 : 100, 1 : 200, 1 : 500, 1 : 1000Large machine beds, engines, building floor plans (1:50, 1:100), site/topographic maps
Enlarging ScaleRF > 12 : 1, 5 : 1, 10 : 1, 20 : 1, 50 : 1Watch escapements, fine fasteners, electronic connectors, small precision springs

Rules for Using Scales in Practice


2.5 Placement of dimensions: Aligned and unidirectional, chain, parallel/baseline and combined type

Text Reading Systems (Aligned vs. Unidirectional)

AspectAligned SystemUnidirectional System
Text OrientationParallel to the dimension line; angled lines carry rotated textAll dimension numbers placed horizontally, regardless of line angle
Reading DirectionReadable from the bottom and right-hand edges of the sheetReadable strictly from the bottom edge of the sheet
Dimension Line BreakDimension line is continuous; text sits cleanly just above the lineDimension line is broken near the midpoint; text sits centered in the gap
Standard PreferenceCommon in manual drafting and architectural drawingsPreferred in modern CAD, CNC, and ISO manufacturing drawings

Arrangement of Dimension Lines

  1. Chain (Continuous) Dimensioning: Successive dimensions are placed end-to-end along a single straight line from feature to feature.
    • Advantage: Saves space and aligns neatly along a single row.
    • Drawback: Manufacturing tolerances accumulate from feature to feature (if three chained segments each vary by +/- 0.1 mm, the overall length can vary by +/- 0.3 mm).
  2. Parallel (Baseline) Dimensioning: All dimensions are measured from a single common datum surface or edge and stacked on parallel dimension lines (shortest dimension closest to the part, longest overall dimension farthest out).
    • Advantage: Completely eliminates cumulative tolerance buildup because every feature depends only on the datum.
    • Drawback: Uses more vertical/horizontal margin space on the sheet.
  3. Combined Dimensioning: Uses chain dimensioning for non-critical intermediate sub-features alongside parallel/baseline dimensioning for datum-critical functional distances. This is the most widely used industrial practice.
  4. Superimposed Running Dimensioning: A space-saving form of parallel dimensioning where all dimensions share a single continuous line starting from a marked zero datum circle (0), with cumulative distances written near each intermediate arrowhead.

Special Feature Dimensioning Rules


2.6 Tolerance dimensioning

No manufacturing process can produce every part to an exact theoretical size. Tolerance is the total permissible variation in a dimension so parts remain functional and interchangeable during assembly without unnecessary machining cost.

Definition

Fundamental Limit and Tolerance Terms (ISO 286)

Unilateral vs. Bilateral Tolerances

AspectUnilateral ToleranceBilateral Tolerance
DefinitionPermissible variation lies entirely on one side of the basic size (either both +/0 or both -/0 or both same sign)Permissible variation lies on both sides of the basic size (one positive deviation, one negative deviation)
Notation Examples25.00 +0.05 / -0.00 or 25.00 -0.01 / -0.0425.00 +/- 0.03 (equal) or 25.00 +0.04 / -0.02 (unequal)
Engineering AdvantageAllows changing tolerance width (tightening or loosening) without shifting the critical mating boundary (standard in limit-gauge hole/shaft production)Useful for non-mating center-to-center distances, casting allowances, or symmetrical profile deviations

Fits and Limit Callout Methods

When a shaft of given limits assembles into a hole of given limits, the relationship is classified into three types of fits:

  1. Clearance Fit: The minimum hole size is always greater than (or equal to) the maximum shaft size (Minimum Clearance >= 0). Parts always assemble freely with play or running clearance.
  2. Interference (Force/Shrink) Fit: The maximum hole size is always smaller than the minimum shaft size (Maximum Clearance < 0, positive interference). Parts must be pressed or thermally shrunk together.
  3. Transition Fit: Tolerance zones of hole and shaft overlap, so assembly may result in either a slight clearance or a slight interference depending on actual manufactured sizes.

Drawing Callout Conventions:


Worked Examples

Example 1

1

On a survey map, a straight road 400 m long is represented by a line 5 cm long. Determine the Representative Fraction (RF) and construct the steps for a Plain Scale capable of measuring up to 1200 m, showing hectometres (100 m) and decametres (10 m) (or hundreds of metres and tens of metres). State the exact reading length to mark 740 m on this scale.

Calculate the Representative Fraction (RF): Convert both lengths to the same unit (centimetres):

  • Length on drawing = 5 cm
  • Actual length = 400 m = 400 x 100 = 40000 cm
  • RF = 5 / 40000 = 1 / 8000 (written as 1 : 8000).

Calculate the Length of Scale (LOS): Maximum length to be measured = 1200 m = 120000 cm.

  • LOS = RF x M_max = (1 / 8000) x 120000 cm = 15 cm (150 mm).

Construction steps for the Plain Scale:

  1. Draw a horizontal baseline AB exactly 15 cm long and build a thin rectangular strip about 10 mm high above it.
  2. Divide the 15 cm line into 12 equal main divisions (each 1.25 cm long, representing 100 m).
  3. Label the end of the first division 0, then label 100, 200, 300, ..., 1100 m to the right.
  4. Subdivide the leftmost 100 m block into 10 equal secondary parts (each 1.25 mm long, representing 10 m), labeled 0, 20, 40, ..., 100 m moving leftward from 0.
  5. Print RF = 1:8000 clearly beneath the scale.
  6. To mark 740 m: Set the divider from 700 m on the right main scale to 40 m on the left secondary subdivisions (spanning 7.4 main divisions = 7.4 x 1.25 = 9.25 cm).
Answer:

RF = 1 : 8000, Length of Scale = 15 cm (12 main parts of 100 m each, first part divided into 10 parts of 10 m each). Distance for 740 m = 9.25 cm (spanning from 40 on the left to 700 on the right).

Example 2

2

An area of 36 sq km on the ground is represented by a 9 sq cm square on a map. Compute the RF, the Length of Scale to read up to 30 km, and describe how to construct a Diagonal Scale to read 10 km blocks, 1 km divisions, and 0.1 km (hectometre) increments, showing a distance of 18.6 km.

Compute the linear RF from the area ratio: Convert 36 sq km to sq cm:

  • 1 km = 1000 m = 100000 cm, so 1 sq km = 100000 x 100000 = 10,000,000,000 sq cm.
  • Actual area = 36 x 10,000,000,000 = 360,000,000,000 sq cm.
  • Linear RF = sqrt(9 / 360,000,000,000) = 3 / 600,000 = 1 / 200,000 (1 : 200000).

Compute the Length of Scale (LOS) for M_max = 30 km:

  • LOS = (1 / 200,000) x 30 km = (1 / 200,000) x 30 x 100,000 cm = 15 cm.

Construction steps for the Diagonal Scale:

  1. Draw baseline AB = 15 cm and divide it into 3 equal main blocks of 5 cm each, representing 10 km per block. Label 0 at the end of the first block, then 10 and 20 km to the right.
  2. Subdivide the leftmost 10 km block into 10 equal parts of 5 mm each, representing 1 km per part (labeled 0, 2, 4, 6, 8, 10 leftward from 0).
  3. Erect a perpendicular AD of height 50 mm at A, divide it into 10 equal horizontal intervals (every 5 mm), and draw horizontal parallel lines across the entire 15 cm frame. Label these horizontal rows 0, 1, 2, ..., 10 upward (each row step adds 0.1 km).
  4. Draw diagonal lines in the leftmost block connecting point 0 on the bottom line to point 1 on the top line, point 1 on the bottom to point 2 on the top, and so on up to point 9 on the bottom to point 10 on the top.
  5. To read 18.6 km: Locate 10 km on the right main scale, 8 km leftward from 0 on the bottom secondary scale, and move 6 horizontal rows upward along the diagonal starting at 8 km. The span from that point horizontally right to the 10 km vertical line equals 18.6 km (drawn length = 18.6 / 30 x 15 = 9.3 cm).
Answer:

RF = 1 : 200,000, Length of Scale = 15 cm (3 main blocks of 10 km, 10 subdivisions of 1 km, 10 vertical diagonal levels of 0.1 km). The drawn span for 18.6 km is 9.3 cm.

Example 3

3

A 50 mm hole-basis shaft-and-hole assembly has the following specified limits:

Determine the upper and lower limits, tolerance of each member, maximum clearance, minimum clearance, and the type of fit. State whether the tolerances are unilateral or bilateral.

Find upper and lower limits and individual tolerances:

  • Hole:
    • Upper Limit (H_max) = 50.000 + 0.025 = 50.025 mm
    • Lower Limit (H_min) = 50.000 - 0.000 = 50.000 mm
    • Hole Tolerance = 50.025 - 50.000 = 0.025 mm (unilateral, since variation lies only above basic size 50.000 mm).
  • Shaft:
    • Upper Limit (S_max) = 50.000 - 0.009 = 49.991 mm
    • Lower Limit (S_min) = 50.000 - 0.025 = 49.975 mm
    • Shaft Tolerance = 49.991 - 49.975 = 0.016 mm (unilateral, since both deviations are negative, on one side of 50.000 mm).

Calculate extreme clearances and classify the fit:

  • Maximum Clearance = H_max - S_min = 50.025 - 49.975 = 0.050 mm
  • Minimum Clearance = H_min - S_max = 50.000 - 49.991 = 0.009 mm

Because even the smallest hole (50.000 mm) is larger than the largest shaft (49.991 mm), there is always positive clearance.

Answer:

Hole limits: 50.025 / 50.000 mm (tolerance 0.025 mm); Shaft limits: 49.991 / 49.975 mm (tolerance 0.016 mm). Both are unilateral tolerances. Maximum clearance = 0.050 mm, minimum clearance = 0.009 mm, resulting in a Clearance Fit.


Exercises

Exercises

Question 1

The distance between two towns is 5 km, and on a map it is shown by a 2.5 cm line. Find the RF, compute the Length of Scale to construct a plain scale measuring up to 40 km, and state the drawn distance corresponding to 27 km.

Compute the Representative Fraction (RF): Convert 5 km to centimetres: 5 km = 5 x 1000 m = 5 x 100000 cm = 500000 cm.

  • RF = 2.5 / 500000 = 1 / 200000 (1 : 200000).

Compute Length of Scale (LOS) for M_max = 40 km:

  • LOS = (1 / 200000) x 40 x 100000 cm = 20 cm (divided into 4 main parts of 10 km each, with the leftmost 10 km part divided into 10 subdivisions of 1 km each).

Compute drawn length for 27 km:

  • Drawing length = (1 / 200000) x 27 x 100000 cm = 13.5 cm (measured from 7 km on the left subdivision to 20 km on the right main scale).
Answer:

RF = 1 : 200000, Length of Scale = 20 cm, and the drawn distance for 27 km = 13.5 cm.

Question 2

Convert (a) 4.0 inches into millimetres and (b) 250 mm into inches. If a machined plate 4.0 inches long is drawn at an enlarging scale of 2 : 1, what length is drawn on paper and what numerical dimension is printed on the drawing (using SI mm units)?

Perform the unit conversions (1 inch = 25.4 mm):

  • (a) 4.0 inches = 4.0 x 25.4 = 101.6 mm.
  • (b) 250 mm = 250 / 25.4 = 9.843 inches (approx. 9.84 in).

Determine drawn paper length vs. printed dimension text:

  • Because 2 : 1 is an enlarging scale (RF = 2), the physical length drawn on paper is 2 x 101.6 = 203.2 mm. (By contrast, at a 1 : 2 reducing scale it would be 50.8 mm.)
  • Regardless of scale, the printed dimension text always shows the true size of the finished part, so the drawing reads 101.6 (with ALL DIMENSIONS ARE IN MM in the title block).
Answer:

(a) 101.6 mm; (b) 9.843 inches. At 2 : 1 enlarging scale, the line is drawn 203.2 mm long on paper, while the printed dimension value remains 101.6.

Question 3

Distinguish between (a) Aligned and Unidirectional dimensioning systems, and (b) Chain and Parallel (Baseline) dimensioning arrangements. Which arrangement avoids cumulative tolerance error, and why?

(a) Aligned vs. Unidirectional systems:

  • Aligned: Dimension text is aligned parallel to the dimension line above it, readable from the bottom and right-hand edges of the drawing sheet.
  • Unidirectional: All dimension text is placed horizontally inside a small break in the dimension line, readable strictly from the bottom edge of the sheet.

(b) Chain vs. Parallel (Baseline) arrangements:

  • Chain dimensioning: Consecutive dimensions are placed end-to-end along one continuous line. Because each feature is located from the previous feature, individual machining errors add up across the chain.
  • Parallel (Baseline) dimensioning: Every feature is dimensioned independently from a single common datum surface on stacked parallel lines. Since each feature depends only on its own tolerance from the datum, parallel/baseline dimensioning eliminates cumulative tolerance buildup.
Answer:

Aligned text follows the dimension line (read from bottom/right) while unidirectional text is always horizontal (read from bottom only). Parallel (baseline) dimensioning prevents tolerance accumulation because every feature is referenced directly to a single common datum rather than to adjacent features.

Question 4

List the recommended clearances and proportions (in mm) for extension lines, dimension lines, and arrowheads per ISO/BIS drawing practice, and state four key rules for placing dimensions clearly on an orthographic drawing.

Standard dimensioning proportions:

  • Extension line gap from object outline: ~1 mm.
  • Extension line overhang past outermost dimension line: 2–3 mm.
  • First dimension line distance from object: 8–10 mm; spacing between successive parallel dimension lines: 6–8 mm.
  • Arrowhead proportions: Closed filled triangle with 3 : 1 length-to-width ratio (~3 mm long x 1 mm wide).

Four key placement rules:

  1. Place dimensions on the view showing the feature's true shape (e.g., circular view for diameters).
  2. Arrange shorter dimensions inside and longer overall dimensions outside so extension lines do not cross dimension lines.
  3. Dimension each feature only once (avoid redundant or duplicate dimensions).
  4. Never use visible outlines, hidden lines, or centerlines as dimension lines, and avoid dimensioning to hidden lines whenever possible.
Answer:

Extension lines keep a 1 mm gap and 2–3 mm overhang; dimension lines sit 8–10 mm from the part (6–8 mm apart); arrowheads have a 3 : 1 ratio (3 x 1 mm). Always dimension true-shape views, keep smaller dimensions inside larger ones, avoid duplicates, and avoid dimensioning to hidden lines.

Question 5

A 30 mm nominal hole and shaft pair has limits:

Compute the hole tolerance, shaft tolerance, maximum clearance, and minimum clearance (or maximum interference), and classify the type of fit.

Compute tolerances:

  • Hole tolerance = 30.033 - 30.000 = 0.033 mm.
  • Shaft tolerance = 30.028 - 30.015 = 0.013 mm.

Compute extreme assembly conditions:

  • Maximum Clearance = H_max - S_min = 30.033 - 30.015 = +0.018 mm (positive clearance).
  • Minimum Clearance = H_min - S_max = 30.000 - 30.028 = -0.028 mm (i.e., 0.028 mm maximum interference).

Classify the fit: Because the hole tolerance zone (30.000–30.033 mm) and shaft tolerance zone (30.015–30.028 mm) overlap—producing clearance in one extreme and interference in the other—this is a Transition Fit.

Answer:

Hole tolerance = 0.033 mm; Shaft tolerance = 0.013 mm; Maximum clearance = +0.018 mm; Maximum interference = 0.028 mm (minimum clearance -0.028 mm). Fit type: Transition Fit.

← Instrumental Drawing, Technical Lettering Practices and TechniquesGeometrical Construction →